KDBR-IV Transformer No-Load/Load Loss & Capacity Analyzer
KDBR-IV Transformer No-Load/Load Loss & Capacity Analyzer

KDBR-IV Transformer No-Load/Load Loss & Capacity Analyzer

Applications:

Designed specifically for power companies and transformer testing facilities to combat electricity theft and unauthorized capacity expansion. It is ideal for field testing of distribution and power transformers with capacities up to 65000 kVA. This equipment enables technicians to accurately measure transformer capacity, no-load loss, load loss, impedance voltage, and other power frequency parameters. It is crucial for identifying unauthorized capacity expansion, ensuring accurate billing, and evaluating transformer performance and efficiency.

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

KDBR-IV integrates transformer capacity testing and characteristic parameter measurement into a single instrument. It features automatic range switching up to 750V/100A and comprehensive analysis including capacity ratings, no-load/load loss, and impedance voltage. The device features waveform distortion correction, temperature compensation, and vector graphic display with an accuracy of ±0.5%. It can store 500 test records and has built-in printer and PC connectivity for convenient and efficient field operation.

Features:

1. Capable of high-precision measurement of the capacity of various distribution transformers;
2. Comprehensive parameter measurement: No-load loss/current, load loss, impedance voltage, RMS/average voltage, current, power, power factor, frequency;
3. Automatic internal range switching enables wide-range voltage/current measurement with simple wiring;
4. Automatic connection verification via vector diagram display during three-phase transformer testing;
5. Single-phase test power supply for single-phase impedance measurement;
6. Direct automatic measurement within the range; measurement range can be extended by connecting external voltage/current transformers;
7. Automatic waveform distortion correction, voltage/current/temperature compensation;
8. Manual setting of impedance voltage and no-load current test current/frequency;
9. Full load testing at full current for transformers ≤1000KVA; full load testing at 1/3 rated current for transformers ≤3150KVA;
10. Maximum 750V/100A with internal protection; no range switching errors;
11. Automatic estimation of the performance class of three-phase oil-immersed distribution transformers;
12. Multiple automatic calibrations: waveform, temperature, and non-rated voltage/current;
13. 320×240 high-brightness LCD screen with touch buttons, adjustable brightness, suitable for all seasons;
14. 40 preset test parameters, with add/delete functionality;
15. Built-in real-time electronic clock for recording test date/time;
16. Panel-mounted thermal printer for convenient on-site printing of test results;
17. Stores 500 test data points, supporting browsing and PC data transfer;
18. Supports external VT/CT for measuring any parameter.

Parameter:

1. Environmental conditions
Temperature: -5C~40C
Relative humidity:<95% (25C)
Altitude:<2500m
External interference: no particularly strong vibrations, no particularly strong electromagnetic fields
External power supply: 220VAC ± 10%, 45Hz~55Hz

2. Measurement range
Capacity: 30KVA to 65000KVA
Voltage: 0-750V, automatic range switching inside the instrument
Current: 0-100A, automatic range switching inside the instrument
Voltage testing range: Ua Ub、Uc、Up 0~750V, Accuracy: 0.2 level;
Current testing range: Ia Ib、Ic、Ip 0~100A, Accuracy: 0.2 level;

3. Testing accuracy
Voltage: 0-100V, ± 0.2% FS; 100~700V,±0.2%
Current: 0-10A, ± 0.2% FS; 10~100A,±0.2%
Power: ± 0.5% (Cos Φ>0.1), ± 1.0% (0.02<cos Φ<0.1)<span="" style="box sizing: border box; text-size-adjust: 100%; -webkit-tap-highlight-color: transparent; margin: 0px; padding: 0px; outline: none; ">
Capacity testing: accuracy level 0.5;
Load loss: accuracy level 0.5;
Impedance voltage: Uk and its percentage Uk% Accuracy: Level 0.5;
No load loss: accuracy level 0.5;
No load current: accuracy level 0.5;

4. Insulation strength
The insulation resistance between the voltage and current input terminals and the casing is ≥ 100M Ω.
The working power input terminal is subjected to a power frequency of 2KV (effective value) between the casing for 1 minute during the experiment.

5. Other indicators
Frequency: 45Hz~65Hz
Dimensions: 400 × 300 × 220mm
Weight: 12Kg (excluding test line)