Products

Products

KDYD2850KV interturn impact voltage tester
KDYD2850KV interturn impact voltage tester

KDYD2850KV interturn impact voltage tester

Applications:

It is suitable for winding interturn insulation detection of large and medium-sized high voltage, AC-DC motor with rated voltage of 15000V and below; It can also be used to detect the insulation between turns of transformer winding and electrical coil win

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

KDYD2850KV interturn impulse voltage tester is suitable for winding interturn insulation detection of large and medium-sized high voltage, AC-DC motor with rated voltage 15000V and below; It can also be used to detect the insulation between turns of transformer winding and electrical coil winding. Due to the motor and transformer windings due to the insulation structure and insulation materials are inconsistent, especially the operator's different technological level, in the winding, wiring, scraping, joint end shaping, handling and other processes will cause different degrees of insulation damage, so that the winding there are various forms of inter-turn insulation failure, therefore, inter-turn insulation is the weak link of the motor and transformer.

Features:

KDYD2850KV interturn impact voltage tester is based on the basic principle of detecting the symmetrical balance of the impedance of the subject. It adopts the shockwave comparison method to carry out the equivalent overvoltage simulation test of the motor and transformer windings with high frequency and high voltage pulses, and uses the oscilloscope of the instrument to observe the waveform comparison and analysis. Can directly, quickly and correctly test winding short circuit and various impedance imbalance fault.

Parameter:

Technical index
Wavefront time: 0.2µs
Polarity: Negative polarity
Pulse peak voltage: 2.0~≥50kV (continuously adjustable)
The peak voltmeter shows: 0~50kV±5%
The voltage below 85% is used continuously, and the voltage above 85% is used intermittently
Pulse energy storage capacitance: 0.05µF±10%
Maximum output power: 62.5J
Discharge frequency: Discharge frequency is 1 time/second
Discharge times: 1-9999 times (5 times recommended)
Insulation resistance: The insulation resistance of the power input to the frame is greater than or equal to 50M ohms;
Dielectric strength: the power input side of the frame can withstand 1500V/50Hz, 1min voltage resistance test, no flying fox, no breakdown phenomenon;
The instrument is equipped with digital storage oscilloscope, which can save waveform and print waveform through computer.
Dimensions (width, height, depth) : 900×600×1550 (width, height, depth)
Weight: 125kg