| Parameter | Specification |
|---|---|
| Rated Output Voltage | 0 – 400 kV (negative polarity), continuously adjustable |
| Rated Output Current | 5 mA |
| Rated Power | 2000 W |
| Voltage Measurement Accuracy | ±(1.0% reading + 0.2 kV) |
| Current Measurement Accuracy | ±(1.0% reading + 2 digits) |
| Ripple Coefficient | ≤0.5% |
| Voltage Stability | ≤1% (with ±10% AC input variation) |
| Overload Capability | - 110% of rated voltage for 10 min (no load) - Charging current up to 1.5× rated (7.5 mA) |
| Input Power | Single-phase AC 220V ±10%, 50 Hz |
| Duty Cycle | Intermittent use; max 30 minutes continuous |
| Operating Environment | - Temperature: –10°C to +40°C - Humidity: ≤85% RH at 25°C (non-condensing) - Altitude: ≤1500 m |
| Capacitive Load Capability | Unlimited; supports 1.5× rated current charging |
| Multiplier Tube Material | Epoxy-glass fiber (air-insulated, no oil or gas) |
| Control Box Features |