Profile:
The instrument adopts computer control, through man-machine dialogue, complete the power frequency voltage breakdown of the insulating medium, power frequency voltage withstand test.
Features:
1. The test curve can be dynamically drawn during the test, and the test curve can be superimposed and contrasted with a variety of colors.
2, the test data can be edited and modified, flexible application;
3, test conditions and test results and other data can be automatically stored;
4, the test report format is flexible, suitable for different needs of different users;
5. The validity of curve data in a group of tests can be artificially selected;
6. Test result data can be imported into EXECL,WORD document editing;
7, the overcurrent protection device has enough sensitivity to ensure that the sample breakdown in 0.1S cut off the power supply;
8, the durability of the instrument operation: the instrument can be continuously operated and used, and there is no need to stop regularly to protect the instrument.
9, the software can set the administrator and each user's own parameters and report storage permissions.
Parameter:
01, Input voltage: AC 220 V.
02, output voltage: AC 0--50KV; Dc 0-50kV.
03, electrical capacity: 3KVA.
04, high voltage classification: 0-50kV, (the whole process is adjustable).
05, boost rate: 0.1KV/ S-5kV /s adjustable (Note: meet the standard requirements and can be set according to user requirements of different boost rate).
06, test mode:
Dc test: 1, uniform voltage boost 2, gradient voltage boost 3, withstand voltage test
Ac test: 1, uniform voltage boost 2, gradient voltage boost 3, withstand voltage test
07, test medium: air.
08, install high sensitivity of the overcurrent protection device to ensure that the sample breakdown in 0.05S cut off the power supply.
09, the instrument is equipped with a fault alarm system to avoid the danger of user operation of the faulty instrument. (Upper computer alarm and lower computer alarm, and zero voltage alarm.)
10, support software sharing different computer Bluetooth remote operation requirements.
11, voltage test accuracy: ≦1%.
12, the test voltage is continuously adjustable: 0-50kV.
13, the current can be collected to mA level and achieve real-time collection.