Products

Products

KDZD5550 voltage breakdown tester
KDZD5550 voltage breakdown tester

KDZD5550 voltage breakdown tester

Applications:

The device has the function of memory of test parameters, the same test conditions do not need to be set for each test, and the power off will still remember the last test set parameters.
The test interface is simple and clear, and is equipped with schematic curve description, different parameters, different curve trend, easy to understand.
The control panel is simple, the function is clearly marked, and the operation is simple.

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

KDZD5550 series voltage breakdown tester is mainly used for testing the breakdown strength and withstand voltage of solid insulating materials under power frequency voltage or DC voltage.

Features:

1, the device for the touch screen operation control.
2, if you need to perform curve analysis, you can be equipped with a computer, only data and curve recording function, no equipment control, to avoid the test personnel in the computer and equipment alternating operation, more humane.
3, the equipment has the function of memory of test parameters, the same test conditions do not need to be set each test, and the power will still remember the last test set parameters.
4, the test interface is simple and clear, and is equipped with schematic curve description, different parameters, different curve trends, easy to understand.
5, the control panel is simple, the function is clearly marked, the operation is simple.
6, can record and display 10 test records at the same time, convenient for comparative analysis of test data. And can discard the unsatisfactory data in real time.
7, the equipment test interface adopts the real-time display mode, which is more convenient to watch the test process.
8, the equipment has a safety warning, the test can not start when the test chamber door is not closed, and a warning will pop up, and the warning will pop up at the full degree (that is: no output of the high voltage transformer), and if the test is opened during the test, the test will automatically end.

Parameter:

Voltage: 5KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 5kV; DC: 0 ~ 5kV
Output power: 0.5kVA
Measuring range: AC: 0.05 ~ 5kV; DC: 0 ~ 5kV
Measurement error: ≤ 2%
Voltage boost rate: 0.025kV/s ~ 0.5/s
Voltage: 10KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 10kV; DC: 0 ~ 10kV
Output power: 1kVA
Measuring range: AC: 0.5 ~ 10kV; DC: 0.5 ~ 10kV
Measurement error: ≤ 2%
Voltage boost rate: 0.05kV/s ~ 1kV/s
Equipment weight: 150kg
Voltage: 20KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 20kV DC: 0 ~ 20kV
Output power: 2kVA
Measuring range: AC: 1 ~ 20kV; DC: 1 ~ 20kV
Measurement error: ≤ 2%
Voltage boost rate: 0.1kV/s ~ 2kV/s
Equipment weight: 150kg
Voltage: 50KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 50kV; DC: 0 ~ 50kV
Output power: 3kVA
Measuring range: AC: 1 ~ 50kV; DC: 1 ~ 50kV
Measurement error: ≤ 2%
Voltage boost rate: 0.20kV/s ~ 5kV/s
Equipment weight: 150kg
Voltage: 100KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 100kV; DC: 0 ~ 100kV
Output power: 10kVA
Measuring range: AC1 ~ 100kV; DC1 ~ 100kV
Measurement error: ≤ 2%
Boost rate: 0.02kV/s ~ 10kV/s
Equipment weight: 300kg
Voltage: 150KV
Input voltage: AC220V 50Hz
Output voltage: AC: 0 ~ 150kV; DC: 0 ~ 150kV
Output power: 15kVA
Measuring range: AC1 ~ 150kV; DC1 ~ 150kV
Measurement error: ≤ 2%
Voltage boost rate: 1kV/s ~ 10kV/s
Equipment weight: 300kg