Products

Products

The ash density and salt density of the insulator under test can be detected simultaneously
The ash density and salt density of the insulator under test can be detected simultaneously

The ash density and salt density of the insulator under test can be detected simultaneously

Applications:

The ash density and salt density of the insulator under test can be detected simultaneously

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

Wuhan KDYM-302L laser salt density test instrument combines gray density test and salt density test with detection technology, which can detect gray density and salt density of the tested insulator at the same time, simplifying the process of insulator pollution detection, and is very suitable for use in inspection sites and laboratories.

Features:

Built-in test special test software, salt dense gray dense integration to complete the test;
Embedded operation, intuitive and fast human-machine interface, parameters can be set flexibly;
Automatic integrated beaker test scheme, after the solution is configured according to the requirements, the method of manual stirring is adopted, and special electrodes are inserted to collect signals;
After the test is completed, please clean the two electrodes with distilled water repeatedly 3 times, and dry them for storage;
Portable design for field testing or laboratory use;
The laser frequency transmission principle is adopted to realize the direct test of gray density without filtering, drying and weighing.

Parameter:

Measuring range
Salt density: 0.01~5.00 mg/cm²
Ash density: 0.01~5.00 mg/cm²
Temperature: 0~100 ℃
Conductivity: 0~100000 us/cm
Measurement accuracy
Salt density: resolution 0.01 bit, full scale accuracy better than ± 2%
Gray dense: resolution 0.01 bit, full scale accuracy better than ± 2%
Temperature: resolution 0.1 bit, accuracy better than ±0.5℃
Conductivity: The resolution is 1/1000 of the electrode range used, and the full-scale accuracy is better than ± 1%
Message output mode
Touch screen: 5.6-inch true color screen, to achieve good human-machine information interaction
Printer: Microprinter prints measurement results directly
U S B: Export measurement data in USB disk mode
Conditions of use
Power Supply: DC: 12.2V / 22Ah lithium battery
Ambient temperature: 0~+50 ℃
Relative humidity: ≤ 85%RH
Storage condition
Ambient temperature: -10~+55 ℃
Relative humidity: ≤ 85%RH
Appearance parameter
Volume: 420mm×340mm×180mm
Weight: About 5.5kg