Profile:
1. The instrument can test 6 insulated boots or gloves at the same time, and measure the leakage current of each test product.
2. The insulating shoe test adopts the dry test method of placing small steel balls inside, which gets rid of the traditional practice of filling the shoes with water to do the test, and it is not easy to dry after the test. Gloves test using water injection test method, the equipment can automatically water gloves, test personnel only need to install the gloves according to the requirements, improve work efficiency.
3. The measured voltage and measured current are compared in real time with high and low voltage to ensure the accuracy of the measured voltage and current value.
4. High and low voltage separation, leakage current is transmitted back to the control box using anti-interference wireless transmission technology, which greatly protects personal safety.
5. Each test has a breaking mechanism, when one of them breaks down or exceeds the set leakage current value, the test will automatically leave the test, does not affect other tests.
6. The instrument uses a large screen LCD Chinese character display, display a large amount of information, a screen at the same time display test voltage, 8 high-voltage leakage current, perpetual calendar, timing time and other parameters as well as Chinese character prompt content.
7. High fineness stepper motor is used to control the booster process of the voltage regulator, and the voltage resistance test is carried out automatically. After the start of the test, the instrument automatically closes and automatically increases the voltage according to the national standard. When the preset voltage is reached, the timing starts, the test voltage is maintained, and the voltage is automatically reduced. After reaching zero, the power is automatically cut off, indicating the end of the test, and the leakage current of each test product is displayed.
8. The insulation shoe test has a special metal grounding tray, and the insulation glove test has a special container, which is easy to operate.
9. The ratio of the test transformer can be set freely and can be matched with the existing transformer of the customer
10. With overcurrent protection function.