Profile:
KD-218 mine cable fault detector is based on the partial discharge method which does not damage the original structure of the cable. It can easily and accurately detect the damaged part of the cable, and it has the function of testing after repair, so it is a fully reliable tool in the current coal mine cable maintenance business.
Features:
KD-218 Mining cable fault detector equipment use environmental conditions:
1, the surrounding medium temperature: - 5℃ - +40℃;
2, the relative temperature of the air: not more than 85%(temperature of 20℃±5);
3, altitude: not more than 2500m;
(4) There is no explosive dangerous medium around, and there is no gas and dust sufficient to corrode metal and destroy electrical insulation in the medium;
5, there is no significant impact vibration, and no rain and snow intrusion.
Parameter:
1, current and voltage: single-phase AC 220V, 50Hz
2, detection DC output voltage: 0-30kV (button control)
3, cable detection accuracy: ±50mm
4, test output DC voltage: 0-30kV (button control)
5, automatic pressure test time: 0-30 minutes (can be set)
6, leakage current test range: 0&mda