Products

Products

KD-216D cable fault multiple pulse comprehensive tester
KD-216D cable fault multiple pulse comprehensive tester

KD-216D cable fault multiple pulse comprehensive tester

Applications:

The time domain analysis method is used to test the low resistance, short circuit, open circuit, high resistance leakage fault and high resistance flashover fault of power cable, communication coaxial cable, local telephone cable, control cable, mining cable and submarine cable of various voltage levels.

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

There are many test methods, such as low voltage pulse method, impulse high voltage current sampling method, DC high voltage flashover method and so on
Polymer rechargeable battery power supply, sample interface for USB type direct microcomputer power supply
Support 4G communication terminal or wireless network card, dedicated 4G software can realize experts remote field real-time test technical services

Features:

KD-216D cable fault multiple pulse comprehensive tester is a portable intelligent cable fault detection instrument designed and manufactured by our company. The instrument is composed of a highly intelligent industrial touch screen integrated computer, a data collector with USB interface, a high-efficiency polymer battery and a charging adapter and accessories. The instrument is small in size, light in weight, easy to use and easy to carry.

Parameter:

Test distance: not less than 60km Test accuracy: ± 0.3m
Operation mode: Dual operation, multi-touch touch and touch mouse operation
Test methods: low voltage pulse method, lightning current method, multiple pulse method, ten pulse method
Storage space: fixed 8G
Minimum test distance (blind area) : 0 ~ 0.5 m or no blind area
Resolution: V/fm; V is the wave transmission velocity m/μs; Software cursor 0.10m accurate fixed point error: ±0.2m
Test error: The system error is less than ±1%
Sampling frequency: 3.125MHz, 6.25MHz, 12.5MHz, 25MHz, 50MHz, 100MHz, 200MHz, 250MHz;
Pulse width: 50ns, 80ns, 100ns, 200ns, 1μs, 2μs, 5μs, 10μs(software automatic matching)
Standby time: can be used continuously for about 6 hours
Weight: 6kg
Overall dimensions: 180mm×300mm×400mm
Ambient temperature: -20℃ ~ +40℃ Relative humidity: 80%
Power supply and power consumption: AC220V±10% no more than 15W
High-frequency high-voltage power supply
Output mode: pulse output, DC output
Output voltage: negative pressure, 0 ~ -35kV continuously adjustable
Working current: ≤40mA
Working mode: single pulse, continuous pulse, DC output
Built-in capacitance: 2uF/35kV(4uF/35kV)
Discharge energy: ≤2450J
Pulse period: 3s ~ 8s