Profile:
KD2684S turns withstand voltage tester adopts pulse waveform comparison method to simulate the equivalent overvoltage of the coil windings of motors and electrical appliances with high voltage pulses. Through the observation, comparison and analysis of the display waveform of the instrument, the insulation between turns of the winding can be measured quickly and correctly. It has good identification performance for inter-turn insulation faults such as inter-turn short circuit, coil corona discharge, local short circuit, wiring error and coil balance.
Features:
KD2684S interturn voltage tester can check the following faults: Interturn insulation breakdown, corona discharge, winding misconnection, miswiring, winding break, turn difference, phase to ground, phase to phase winding or local short circuit between winding and core can be used for single-phase motors, three-phase small and medium-sized motors, micro motors, special motors, electric tool motors, transformers (including switching power supply transformers), relays and electrical appliances containing electromagnetic wire winding between turns and layers Edge strength test.
Parameter:
1, the peak voltage: 500V ~ 10kV continuous adjustable
2, peak test error: ±5% (1kV-10kV)
3, waveform rise time: 0.2μS (+0.3μS; -0.1μS) or 1.2μS (tolerance ±30%)
4, working power supply: 220V±10% 50HZ
5, power consumption: ≤800W
6. Overall size: 90×46×55cm
7. Weight: 70Kg