Products

Products

KDCJ-20kV solar transient overvoltage tester
KDCJ-20kV solar transient overvoltage tester

KDCJ-20kV solar transient overvoltage tester

Applications:

KDCJ-20kV impact pressure testing machine is one of the basic items of high voltage test of power equipment. After design, manufacture and maintenance, it is necessary to carry out impact test verification or inspection.

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

KDCJ-20kV impact voltage tester is an intelligent control and testing system designed for the high voltage impact generator produced by our company. It adopts programmable controller and computer technology in technology, and the control and measurement functions are automatically realized, thus simplifying the system composition and greatly improving the reliability of the system. This enhances the safety of the system in high voltage and high current tests and prevents the equipment from being subjected to the transient process of high voltage discharge. The operation interface has good man-machine dialogue function, the operation process is convenient and simple, and has the characteristics of intelligence.

Features:

Thyristor voltage regulation mode, with charging voltage feedback measurement system; The impact high pressure probe adopts soft silicone wire, which is resistant to high pressure, aging, high temperature and acid and alkali, ensuring the accuracy of each output measurement.
Easy to operate, large touch LCD screen, WYSIWYG simple operation; Constant current charging mode controlled by function is adopted. The charging voltage and charging time can be directly input from the LCD panel
Standardization: Built-in international standard grade parameters, easy to operate, LCD panel can indicate the charging voltage and charging process of the impact generator. With charging abnormal protection function, can automatically or manually send trigger signal

Parameter:

1, DC voltage: ≥20kV (1.0~20.0kV); Setting resolution 0.1kV
Pre-shock time: 1.2μs±30%;
Half time after wave: 50μs±20%;
2. Peak voltage
Low: 1kV ~ 4.991kV±3%;
High: 5kV ~ 19.991kV±3%;
3, impact time interval: 5 ~ 99 (S)
Set resolution 1s
Alarm delay 2s
Pressure times: Impact times 1 ~ 9999 times
4, control display function: DC charging voltage, charging time timing, the main power contactor cutting state
5, polarity: positive and negative; Internal resistance: < 500Ω;
6, working power supply rated voltage: ~ 220V±10% 50Hz;
7, power consumption: 50VA