Products

Products

KDYD 5/50 20KVA/120KVA dry-type high-voltage AC/DC test transformer
KDYD 5/50 20KVA/120KVA dry-type high-voltage AC/DC test transformer

KDYD 5/50 20KVA/120KVA dry-type high-voltage AC/DC test transformer

Applications:

Dry type high-voltage AC/DC test transformer is an important testing equipment, especially suitable for on-site insulation performance testing of various electrical equipment in power systems and various power users. ‌

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

It can not only be used for AC withstand voltage testing, but also provide DC high voltage, providing high voltage for various high-voltage tests, thus meeting the high voltage power supply requirements in various voltage systems or devices.

Features:

1. High voltage, low voltage, current zero position indication, power indication, working indication, timing indication.
2. Equipped with a low-voltage input ammeter and overcurrent protection circuit.
3. Equipped with a time relay, it can effectively control the test time.
4. Equipped with an isolation knife switch, the power circuit can have a clear break through the knife switch.
5. Overcurrent protection, zero start protection, sound and light language alarm reminder.
6. Adopting a new type of time relay, the timing range is wider (1S-99H).
7. Adopting a new type of current relay, it is more precise and reliable, ensuring personal and equipment safety.
8. The high-voltage coil of the test transformer is a cylindrical multi-layer tower, made of high-quality polyester enameled wire and high voltage insulation material.
9. It has the characteristics of light weight, small size, easy mobility, and superior performance.
10. The test transformer (above 5kVA) is equipped with movable iron wheels.

Parameter:

1. Console
●Rated capacity: 1.5-100kVA
●Rated output current: 7.5-232.5A
●Rated output voltage: 0-430V
● Input power supply: three-phase AC 380V ± 10% (single-phase AC 220V ± 10%); 50Hz±5 Hz
● Input current: 7.5-250A
●Timing length: 0~9999S (special mode can be used for long-term work)
●Voltage accuracy: ≤ 1.0% ± 1 word (F.S)
●Current accuracy: ≤ 1.0% ± 1 word (F.S)
●Explanation: If there are special parameter requirements, design and production can be carried out according to the user's technical parameters.
2. Epoxy resin dry-type test transformer
●Rated capacity: 1.5-100kVA
●Low voltage side voltage: 400V
●Low voltage side current: 7.5-250A
●High voltage side AC output voltage: 0-300kV
●High voltage side AC output current: 0-3000mA
●Measurement ratio: 1000:1
●Impedance voltage: 4-9%
●Output voltage waveform: sine wave
●Variable ratio error: < ± 1%
● Waveform distortion rate: ≯ 3%
● Allowable continuous full load working time: ≮ 1-2 hours (temperature rise of 50 ℃)
● No load loss: 0.2% to 0.4.0%
●Voltage measurement accuracy: 1.0% FS ± 3 words
●Current measurement accuracy: 1.0% FS ± 3 words