Products

Products

KDXZ-II 35kVSeries resonance withstand voltage test device
KDXZ-II 35kVSeries resonance withstand voltage test device

KDXZ-II 35kVSeries resonance withstand voltage test device

Applications:

A wide range of applications. The whole set of frequency conversion series resonant high voltage test equipment conforms to the relevant national high voltage test regulations and requirements, and is suitable for high voltage and large capacity power equ

  • Response within
    24 hours

  • Free warranty
    12 month

  • On-line training
    Support

Profile:

Rated capacity: 270kVA;
Input power supply: single-phase 220 or three-phase 380V voltage, frequency is 50Hz;
Rated voltage: 45kV; 90kV; 135kV; 270kV;
Rated current: 6A; 3A; 2A; 1A;
Working frequency: 30-300Hz;
Device output waveform: sine wave
Waveform distortion rate: output voltage waveform distortion rate ≤1%;
Working time: continuous 60min under rated load; Overpressure 1.1 times 1 minute;
Temperature rise: Temperature rise ≤65K after continuous operation under rated load for 60min;
Quality factor: device Q≥30(f=45Hz);
Protection function: over-current, over-voltage and flashover protection for test subjects (see inverter power supply section for details);
Measurement accuracy: 1.5 effective value of the system;

Features:

1. Frequency conversion power supply reliable and durable, leading technology. Our independent research and development of independent production of inverter control power technology leading in China, and obtained a number of national patents. Dual CPU architecture system is adopted to achieve rapid measurement and control, and the system voltage stability accuracy reaches 1%. The module integrates drive and protection in IGBT, which greatly improves the reliability of power circuit and whole machine. Soft switching technology can effectively reduce interference and meet the requirements of office discharge test.
2. Intelligent software menu, humanized design. Large screen intelligent display software menu built-in test parameters menu, customers can according to the test procedures and actual needs, input the required test voltage and test time; Built-in automatic, semi-automatic, manual three test modes, friendly interface, easy and convenient test operation. Test data can be stored on screen, and can be read, built-in micro printer, reserved interface for external computer.
3. Automatic tuning mode. Using the newer fast tracking method, finding the resonant frequency point only takes about 30 ~ 40S, and locking the resonant frequency after tuning is completed. If no resonance point is found, Tuning Failed is displayed in the prompt area. If there is no resonance point between 30Hz and 300Hz during manual tuning, the prompt area displays "No resonance point". In this case, the booster circuit is automatically cut off. Do not continue to increase the pressure, to ensure the safety of the test products, equipment, personal safety.

Parameter:

1, excitation transformer 15kVA/4/8/16kV/0.4kV 1
Rated capacity: 15kVA;
 Input voltage: 0-400V, single phase;
Output voltage: 4/8/16kV
 Structure: dry type;
 Weight: approx. 58kg;
2, frequency conversion power supply 15kW/220/380V 1
 Rated output capacity: 15kW
 Power supply: 220/380±10%V(single/three-phase), power frequency
 Output voltage: 0-400V, single phase,
 Rated input current: 37.5A
Rated output current: 37.5A
 Voltage resolution: 0.01kV
 Voltage measurement accuracy: 1.5%
 Frequency adjustment range: 30 to 300Hz
 Frequency adjustment resolution: ≤0.1Hz
 Frequency stability: 0.1%
 Running time: 60 minutes continuously at the rated capacity
The maximum component temperature of continuous operation for 60 minutes at rated capacity ≤65K;
 Noise level: ≤50dB