Profile:
KDZG series DC high voltage generator adopts medium frequency voltage doubling circuit, applying PWM medium frequency pulse width modulation technology, closed-loop adjustment, using voltage feedback, so that the voltage stability is improved. The high power IGBT device and its driving technology are used, and special shielding, isolation and grounding measures are adopted according to electromagnetic compatibility theory. The DC high voltage generator has high quality, portable, and can withstand rated voltage discharge without damage.
Features:
1, smaller volume, lighter weight, more beautiful, more reliable, easy to operate, complete functions, easy to use in the field.
2, the use of new PWM intermediate frequency pulse width modulation technology, pulse train logic array modulation, the use of high-power IGBT devices and voltage feedback, so that the output high voltage stability is higher, the ripple coefficient is smaller.
3, high precision, accurate measurement. Voltage and ammeter are digital display, voltage resolution is 0.1kV, current resolution is 1uA, the voltage meter on the control box directly displays the voltage value added to the load test, no need to use the voltage divider, simple wiring. The instrument has a high and low voltage end to measure the leakage current, and the high voltage end is displayed by a circular shielded digital meter, which is not afraid of discharge impact and has good anti-interference performance, and is suitable for field use.
4, high voltage regulation stability, smooth range voltage regulation, output voltage regulation using imported single multi-turn potentiometer, stable voltage boost process, high adjustment accuracy.
5, negative polarity output, zero start, continuous adjustable, over voltage, over current, back to zero, ground protection, special break line protection and other protection functions. The automatic protection circuit has strong function, perfect and reliable protection, so that the operation is safe, and various technical indicators are better than the industry standard.
Parameter:
Rated voltage (kV) : 0 ~ 120kV, 0 ~ 200kV continuously adjustable; Negative output
Rated current (mA) : 2mA, 3mA, 5mA, 10mA,
Rated power (W) : 360 ~ 1200W
Voltage measuring pad accuracy: digital display topsoil (1.0% ±0.2kV)
Current measurement accuracy: digital surface (1.0% reading ±2)
Ripple coefficient: ≤0.5%
Voltage stability: random fluctuation, W1% when the power supply voltage changes ±10%
Overload capacity: the no-load voltage can exceed the rated voltage by 10%. The maximum charging current for ten minutes is L5 times the rated current
Power supply: single-phase AC 50HZ 220V 10%
Working mode: Intermittent use, a continuous time of up to 30 minutes
Working environment: Temperature, 10 ~ 40°C
Relative humidity, not more than 85% at room temperature of 25°C (no condensation)
Altitude, below 1,500 meters