Technical support

Technical support

26 Aug-2024

Working principle and characteristics of circuit resistance tester

The design of the circuit resistance tester adopts high reliability high-power integrated circuits, consisting of a DC constant current source, preamplifier, A/D converter, indicator device, etc. It is a low value resistance measuring instrument with mill

23 Aug-2024

Introduction to Precautions, Technical Indicators, and Principles for the Use of Zinc Oxide Surge Ar

KDYZ-201 Zinc Oxide Surge Arrester Tester is a specialized instrument used to test the electrical performance of zinc oxide surge arresters. This instrument is suitable for live or power-off detection of various voltage levels of zinc oxide surge arrester

14 Aug-2024

The function and function of a high current generator

High current generators are widely used in power testing in the power industry. They are mainly used to conduct voltage, current, time and other tests on relays, and have the characteristics of strong functionality, simple and convenient use.

02 Aug-2024

User Manual for Power Frequency Voltage Withstand Test Device

The power frequency withstand voltage test device consists of a power frequency test transformer and a withstand voltage control box, which perform insulation strength tests on electrical appliances, electrical components, etc. under specified voltages.

02 Aug-2024

Explanation of the working principle of the insulation oil dielectric loss tester

The insulation oil dielectric loss tester is a high-precision instrument used for measuring the dielectric loss angle and volume resistivity of liquid insulation media such as insulation oil.

02 Aug-2024

General safety technical requirements for ultra-low frequency high voltage generators

The ultra-low frequency high-voltage generator should have an automatic grounding discharge device, and the residual charge on the test sample should be automatically discharged within 5 seconds under the rated capacitance and rated output voltage.

02 Aug-2024

Operation Guide for Test Transformer Console

Before operation, the maximum working current should be calculated based on the capacity and voltage level of different test samples, and the current protector should be adjusted accordingly.

01 Aug-2024

Interface description of harmonic superposition testing unit for relay protection tester

The "harmonic superposition" testing unit of the relay protection tester can achieve the superposition output of various harmonic components of three-phase voltage and current, and is used to test the working behavior of power system equipment under v